by Uten Yarach, Myung-Ho In, Itthi Chatnuntawech, Berkin Bilgic, Frank Godenschweger, Hendrik Mattern, Alessandro Sciarra, Oliver Speck
Abstract:
Purpose To describe a model-based reconstruction strategy for single-shot echo planar imaging (EPI) that intrinsically accounts for k-space nonuniformity, Nyquist ghosting, and geometric distortions during rather than before or after image reconstruction. Methods Ramp sampling and inhomogeneous B0 field-induced distortion cause the EPI samples to lie on a non-Cartesian grid, thus requiring the nonuniform fast Fourier transform. Additionally, a 2D Nyquist ghost phase correction without the need for extra navigator acquisition is included in the proposed reconstruction. Coil compression is also incorporated to reduce the computational load. The proposed method is applied to phantom and human brain MRI data. Results The results demonstrate that Nyquist ghosting and geometric distortions are reduced by the proposed reconstruction. The proposed 2D phase correction is superior to a conventional 1D correction. The reductions of both artifacts lead to improved temporal signal-to-noise ratio (tSNR). The virtual coil results suggest that the processing time can be reduced by up to 75\%, with a mean tSNR loss of only 3.2\% when using 8-virtual instead of 32-physical coils for twofold undersampled data. Conclusion The proposed reconstruction improves the quality (ghosting, geometry, and tSNR) of EPI without requiring calibration data for Nyquist ghost correction. Magn Reson Med 78:2250–2264, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Reference:
Model-based iterative reconstruction for single-shot EPI at 7T (Uten Yarach, Myung-Ho In, Itthi Chatnuntawech, Berkin Bilgic, Frank Godenschweger, Hendrik Mattern, Alessandro Sciarra, Oliver Speck), In Magnetic Resonance in Medicine, volume 78, 2017.
Bibtex Entry:
@article{yarach_model-based_2017,
title = {Model-based iterative reconstruction for single-shot {EPI} at 7T},
volume = {78},
url = {https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.26633},
doi = {10.1002/mrm.26633},
abstract = {Purpose To describe a model-based reconstruction strategy for single-shot echo planar imaging (EPI) that intrinsically accounts for k-space nonuniformity, Nyquist ghosting, and geometric distortions during rather than before or after image reconstruction. Methods Ramp sampling and inhomogeneous B0 field-induced distortion cause the EPI samples to lie on a non-Cartesian grid, thus requiring the nonuniform fast Fourier transform. Additionally, a 2D Nyquist ghost phase correction without the need for extra navigator acquisition is included in the proposed reconstruction. Coil compression is also incorporated to reduce the computational load. The proposed method is applied to phantom and human brain MRI data. Results The results demonstrate that Nyquist ghosting and geometric distortions are reduced by the proposed reconstruction. The proposed 2D phase correction is superior to a conventional 1D correction. The reductions of both artifacts lead to improved temporal signal-to-noise ratio (tSNR). The virtual coil results suggest that the processing time can be reduced by up to 75\%, with a mean tSNR loss of only 3.2\% when using 8-virtual instead of 32-physical coils for twofold undersampled data. Conclusion The proposed reconstruction improves the quality (ghosting, geometry, and tSNR) of EPI without requiring calibration data for Nyquist ghost correction. Magn Reson Med 78:2250–2264, 2017. © 2017 International Society for Magnetic Resonance in Medicine.},
number = {6},
journal = {Magnetic Resonance in Medicine},
author = {Yarach, Uten and In, Myung-Ho and Chatnuntawech, Itthi and Bilgic, Berkin and Godenschweger, Frank and Mattern, Hendrik and Sciarra, Alessandro and Speck, Oliver},
year = {2017},
keywords = {geometric distortion, model-based reconstruction, Nyquist ghost, single-shot EPI},
pages = {2250--2264}
}