by Robert Frysch, Tim Pfeiffer, Sebastian Bannasch, Georg Rose, Steffen Serowy, Martin Skalej
Abstract:
Perfusion imaging is an essential method for stroke diagnostics. One of the most important factors for a successful therapy is to get the diagnosis as fast as possible. Therefore our approach aims at perfusion imaging (PI) with a cone beam C-arm system providing perfusion information directly in the interventional suite. For PI the imaging system has to provide excellent soft tissue contrast resolution in order to allow the detection of small attenuation enhancement due to contrast agent in the capillary vessels. The limited dynamic range of flat panel detectors as well as the sparse sampling of the slow rotating C-arm in combination with standard reconstruction methods results in limited soft tissue contrast. We choose a penalized maximum-likelihood reconstruction method to get suitable results. To minimize the computational load, the 4D reconstruction task is reduced to several static 3D reconstructions. We also include an ordered subset technique with transitioning to a small number of subsets, which adds sharpness to the image with less iterations while also suppressing the noise. Instead of the standard multiplicative EM correction, we apply a Newton-based optimization to further accelerate the reconstruction algorithm. The latter optimization reduces the computation time by up to 70\%. Further acceleration is provided by a multi-GPU implementation of the forward and backward projection, which fulfills the demands of cone beam geometry. In this preliminary study we evaluate this procedure on clinical data. Perfusion maps are computed and compared with reference images from magnetic resonance scans. We found a high correlation between both images.
Reference:
C-arm perfusion imaging with a fast penalized maximum-likelihood approach (Robert Frysch, Tim Pfeiffer, Sebastian Bannasch, Georg Rose, Steffen Serowy, Martin Skalej), In Proc. SPIE, volume 9033, 2014.
Bibtex Entry:
@inproceedings{frysch_c-arm_2014,
	address = {San Diego},
	title = {C-arm perfusion imaging with a fast penalized maximum-likelihood approach},
	volume = {9033},
	url = {http://dx.doi.org/10.1117/12.2043450},
	doi = {10.1117/12.2043450},
	abstract = {Perfusion imaging is an essential method for stroke diagnostics. One of the most important factors for a successful therapy is to get the diagnosis as fast as possible. Therefore our approach aims at perfusion imaging (PI) with a cone beam C-arm system providing perfusion information directly in the interventional suite. For PI the imaging system has to provide excellent soft tissue contrast resolution in order to allow the detection of small attenuation enhancement due to contrast agent in the capillary vessels. The limited dynamic range of flat panel detectors as well as the sparse sampling of the slow rotating C-arm in combination with standard reconstruction methods results in limited soft tissue contrast. We choose a penalized maximum-likelihood reconstruction method to get suitable results. To minimize the computational load, the 4D reconstruction task is reduced to several static 3D reconstructions. We also include an ordered subset technique with transitioning to a small number of subsets, which adds sharpness to the image with less iterations while also suppressing the noise. Instead of the standard multiplicative EM correction, we apply a Newton-based optimization to further accelerate the reconstruction algorithm. The latter optimization reduces the computation time by up to 70\%. Further acceleration is provided by a multi-GPU implementation of the forward and backward projection, which fulfills the demands of cone beam geometry. In this preliminary study we evaluate this procedure on clinical data. Perfusion maps are computed and compared with reference images from magnetic resonance scans. We found a high correlation between both images.},
	booktitle = {Proc. {SPIE}},
	author = {Frysch, Robert and Pfeiffer, Tim and Bannasch, Sebastian and Rose, Georg and Serowy, Steffen and Skalej, Martin},
	year = {2014},
	pages = {90332M--90332M--8}
}